Goodman furnace heat exchanger recall

Goodman furnace heat exchanger recall. to go back to supply house pick up new exchanger and do warranty, and argue with counter guy it Goodman 2821301S Primary Heat Exchanger . 2921304S. The return ducts will suck and cold air from your home and pass it along throughout the heat exchanger so that it can be heated. Heat exchangers in the furnace can crack. Choosing between maintenance and upgrading a furnace or boiler can be a difficult decision, but luckily there are some simple rules to help you make the right one. This retrofit involves 150,000- and 200,000-Btu oil furnaces manufactured by Ducane and distributed under the following brand names and model numbers: Repair Clinic is your one-stop furnace supply shop for Goodman Furnace Parts, providing same-day shipping throughout the United States as well as 24/7 online help to diagnose the issue, locate your specific Goodman repair parts, and even aid with the repair! Evaporator Coil Drain Pan Safety Recall. The matched furnace is a Daikin, Goodman, or Amana® brand Ultra Low NOx gas furnace. The room thermostat reacts to a demand for heat. Dec 2, 2023 · What is the cause of heat exchanger cracks? An overheating furnace causes nearly all premature heat exchanger cracks. We are here to help you get the most out of your product, offering the tools and resources to show you how. On this service call I will show how to remove and reinstall th The recall now also includes those drain pans installed with certain configurations of competitor branded (not Goodman, Daikin or Amana-branded) non-condensing residential gas furnaces in a vertical, or "up-flow," coil configuration, as shown in the table below: Type Coil Configuration Affected Furnace Brands Affected Coil Serial Numbers Dates Apr 3, 2008 · Description: This recall involves Goodman single package gas-electric heating and cooling units with model numbers GPG13480901AC, GPG13481151AC, GPG13600901BB, GPG13601151BB, and GPG13601401BB, and with serial numbers beginning 0712, 0801, and 0802. Units: About 56,000 (In addition, about 5,522 were sold in Canada) Description: This recall involves Daikin FIT, Amana Brand S-series and Goodman SD heat pumps that provide heating and cooling. #1 There may be turbulator/restrictor inserts in the secondary heat exchanger tubes to increase surface area and efficiency. Dec 8, 2009 · Units: About 30,000 (This recall was first announced in Aug. 2% to maximize the heat transfer efficiency and lower blower noise. This one gives a step by step procedure of how to replace the Goodman (Janitrol) model GMP heat exchanger. Sep 14, 2023 · When the pilot light is lit on a furnace, the furnace will begin channeling hot combustion gases inside of the heat exchanger allowing the heat to be distributed and moved to the vents. 2921301S. 2921302S. There should be a steady light on the control board. The matched furnace has a Blower Guard Kit. Package Unit Serial Plate Recall. This indicates Mar 5, 2022 · Next, see if you have cracked or damaged the burner chamber or heat exchanger because that can trigger the rollout switch and stop the furnace. Complex Mechanical Failures: Some problems, such as a faulty heat exchanger or malfunctioning furnace control board, are complex. Mar 25, 2024 · Goodman Furnace Reviews. *Complete warranty details are available from your local dealer or at www. For more tips on keeping your machine in good working order Dec 16, 2019 · Stick it in the plenum about foot downstream from where it goes horizontal so it does not see the heat exchanger and get radiant heat fooled. Corrosion and cracking on other parts of the furnace. The contractor may also inspect the flue vent for any obstructions (ex: bird nest) that could restrict exhaust from escaping. Jul 28, 2022 · DCT is contacting all registered consumers where records indicate their gas furnace system is subject to the expanded recall. Nov 21, 2023 · These high-efficiency furnaces differ from 80% induced-draft furnaces in that they have a dedicated air intake, a primary and secondary heat exchanger, and a condensate assembly. If you have a Goodman furnace, fret no more! This comprehensive g Dec 5, 2011 · Heating Mode. 2 Consumer Affairs Department Goodman Manufacturing Company, L. S. <br>These furnaces are designed to be used with a Check to see if there is power to the furnace. July 28, 2022 — Goodman Manufacturing Company re-announced a recall for more than 300,000 evaporator coil drain pans in the U. A formaldehyde-like smell. If the limit is open, the furnace will remain inoperable until the limit is closed. How to fix a cracked Goodman furnace heat exchanger Feb 20, 2017 · ya, My bet is a crimp ring failure. Units: About 4,100 Description: This recall involves 80% efficiency gas-fired furnaces sold under the Goodman, Amana and Daikin brand names used with home heating and cooling systems. and Canada after dozens of fires were reported. ) hell Ive been replacing some of these x-changers in attics in one complex it takes me 1/2 hr. The same goes if the appliance has a tripping limit or rollout switch. FurnacePartSource. Q: Are heat exchangers only used for heating purposes? A: No, a heat Jan 15, 2024 · A furnace should last for at least 10 to 15 years, and its components should last almost as long. This retrofit involves 150,000- and 200,000-Btu oil furnaces manufactured by Ducane and distributed under the following brand names and model numbers: Product Recall Information : June 27, 2024: FIT Recall: FIT Recall: June 13, 2024: Package Unit Serial Plate Recall: Recall Info: August 3, 2023: Amana PTAC DigiAir Recall: PTAC DigiAir Recall: November 18, 2021 (Expanded January 11, 2024) Amana Coil Drain Pan Recall: Coil Drain Pan Recall Info Resources: March 1, 2018: Amana PTAC Motor Recall #6 Unpleasant Physical Signs Especially When You’re Near A Faulty Heat Exchanger Furnace. heat exchanger featured in Goodman brand gas furnaces is likely the most essential component in a gas furnace’s performance. Shop now and get same-day shipping on this 0257F00173S Heat Exchanger. Warranties can save you a great deal of money on repair costs, and to make sure you get the longest terms possible, register the furnace with 6 days ago · Goodman ’s heat pumps provide year-round heating and cooling with ratings of up to 22. 5 SEER2 and a Heating Season Performance Factor 2 (HSPF2) of up to 8. We have fast FREE SHIPPING on all orders over $99 and ship all orders within 1 business day. The blower motor blows air through the return vent, past the heat exchanger, and into the home’s venting. Electrical problems pose serious safety risks and require professional diagnosis and repair. on Thursday recalled more than 300,000 evaporator coil drain pans installed with residential condensing gas furnaces after fielding 23 reports of fires causing damage. Product Recall Information. Goodman had 4,100 recalls in 2017. However, it is possible that other parts and controls in the furnace may also be in need of replacement at this point. If it is available, the best way to repair a cracked heat exchanger is to remove the damaged cell and replace it. Furnace heat exchanger life: In this article we discuss residential forced warm air furnace heat exchanger life in more detail, explaining the factors that impact the life of the heat exchanger, things you should do to maximize the life of the furnace heat exchanger, and similarly, things you should not do because they are likely to destroy your furnace before its time. Over time, the heat stress causes cracks near weak areas such as bends or welds. Jan 12, 2024 · Heat exchanger issues are critical problems that can affect the safety and efficiency of your heating system. As a solution to new legislation controlling emissions, steel bars were fitted at the top of furnaces, causing overheating. Feb 6, 2021 · Cracks in the heat exchanger or furnace; Soot buildup; Rusty heat exchanger; Pooled water on the floor; Repairing a Heat Exchanger Versus Buying a New Furnace or Boiler. There are 2 other theoretical possibilities. When your current furnace breaks, it’s To receive the 20-Year Heat Exchanger Limited Warranty (good for as long as you own your home), and 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. There are pictures of the crack below. The diameter, tubular heat exchanger • Stainless-steel secondary heat exchanger • Two-stage convertible gas valve auto- matically adjust to high or low stage • Durable Silicon Nitride igniter • Quiet single speed draft inducer • Self-diagnostic control board with constant memory fault code Dec 8, 2009 · Units: About 30,000 (This recall was first announced in Aug. It applies to coils from the model families in Table 1 with serial numbers between 1901 and 2101, sold from January 2019 to June 2021. ) Expands Recall of Evaporator Coil Drain Pans to Include Additional Units. During an open limit, the circulating air blower will be energized. This retrofit involves 150,000- and 200,000-Btu oil furnaces manufactured by Ducane and distributed under the following brand names and model numbers: If you want to make sure your HVAC system stays dependable, this Goodman furnace maintenance guide explains what you can do to make sure your heating system stays in good working order when you need it the most. 6. The status light will blink four (4) times. If key parts fail, such as the heat exchanger or control module, or repair costs are more than 50% of the cost of a new product, it may be better to replace the unit. Most cheap furnace brands only have a primary heat exchanger. In cooperation with the U. However, most homeowners pay around $1,750. November 18, 2021 (Expanded January 11, 2024) Goodman Coil Drain Pan Recall. The matched furnace is a Daikin, Goodman, or Amana brand condensing furnace with a constant volume (variable speed ECM) from the model number families listed below in Table 2. All Goodman Heat Exchangers are brand new in the original factory packaging and are guaranteed to fit and function properly. Now, a cracked heat exchanger can leak all kinds of toxic gases inside your home. I hope you dont price all your jobs like you would the heat exchanger ("takes about 1-hr. The manufacturer said it has received 26 reports of fires involving the recalled evaporator coil drain pans, including 3 reports of fires since the recall was Recall Details. Goodman GMH950453BXAA Gas Furnace OEM Repair Parts. The Goodman (Janitrol) GMP model gas furnace had a large number of heat exchanger problems. Do not operate a Goodman furnace with a compromised heat exchanger and burner or combustion chamber. (“Goodman”) is voluntarily recalling certain molded plastic evaporator coil drain pans that were sold from approximately January 2019 through November 2021. The rust continues inside the primary heat exchanger at the seams. Nov 27, 2023 · Low cost, with Goodman gas furnaces starting at less than $700; The best warranties in the home heating industry including replacement of the entire furnace if the heat exchanger fails on top models; A new era began for Goodman in 2012 when the brand was purchased by Daikin Global, one of the world’s first-tier HVAC manufacturing companies. May 22, 2013 · GMP100-5 Parts List: Blower Motor — B1340023S, Goodman/Janitrol, 3/4 HP, Direct Drive Vent/Inducer Motor — B1859005, Goodman/Janitrol Gas Valve — 0151M00013S No Heat - Goodman gas furnace - condemned with cracked heat exchanger! ⚠️Do not attempt this if you are not qualified and/or trained ⚠️Let's Make The Trades With predefined registration conditions, Goodman will furnish a 10-year parts limited warranty that provides replacement part(s) for any part that is found to be defective due to workmanship or materials under normal use and maintenance, and a lifetime heat exchanger limited warranty**(good for as long as you own your home). Aug 1, 2024 · A heat exchanger in simple terms is a heating component inside of a furnace that transfers heat to the surrounding air, which is commonly distributed throughout the home through a furnaces ducting Goodman GMH950453BXAB Gas Furnace OEM Repair Parts. This 0257F00173S Heat Exchanger is a genuine replacement part for furnaces and is available now from Repair Clinic. com. Cleaning the Heat Exchanger: Important Note: Cleaning the heat exchanger is a delicate task and should only be performed by a trained and certified HVAC technician. This range from headaches, nausea, nose and eye irritation, and even insomnia. To receive the Lifetime Heat Exchanger Limited Warranty (good for as long as you own your home) and 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. A Goodman furnace leaking water is a danger both for the device itself and people. second, why didn't the customers CO detector go off. The make and model of the furnace won’t matter. Both have furnace options with two-stage heating. The video below demonstrates how to determine if the heat exchanger has failed. The duration of warranty coverage in Texas and Florida differs in some cases. The Ducane Company initiated the recall after it found a crack in one of its furnaces. May 3, 2024 · Replacing a furnace heat exchanger can cost anywhere from $800 to $5,000, depending on factors like the furnace’s type, size and age. 4. Jan 11, 2021 · If your heat exchanger has gone bad, you have two options: replace the heat exchanger or replace the furnace. Goodman Heat Exchangers. . They are usually more affordable than some high priced competitor HVAC furnace brands such as Trane, or Carrier. A broken heat exchanger can cause flame failure and dangerous CO gas in the structure. Notably, the heat exchanger is enclosed in a metal chamber to distribute warm air in your entire home safely. Some models by both brands have energy star ratings. Dec 26, 2023 · Apart from the loud noise from a cracked heat exchanger, there are other signs that could indicate your Goodman furnace heat exchanger has a crack: A yellow flame; Plenty of soot produced by the furnace. 771241771241 There is a humidifier attached but it hasn't run in a long time. The problems which prompted a recall of these furnaces include burner and heat exchanger failure, leading to both the possibility of fires and the escape of hazardous gases. Heat exchangers Lifetime heat exchanger warranty; 10-year parts warranty; 10-year unit replacement warranty; Curious about the unit replacement warranty? It means that Goodman will replace the entire furnace if the heat exchanger fails during the coverage period. reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. Troubleshooting heat exchanger issues involves the following steps: Goodman and York are also similar when it comes to warranty protection because just about every York furnace comes with a lifetime heat exchanger warranty, a 10-year parts warranty, and a five- or 10-year Complete Assurance warranty, which is equivalent to Goodman’s unit replacement guarantee. goodmanmfg. The quoted price for the heat exchanger replacement is $900. cpsc. This bulletin provides instructions for field modifications required for certain evaporator coil drain pans paired with condensing furnaces in upflow applications. Goodman will also assist consumers in gathering information on Nov 26, 2023 · Goodman Two Stage Furnaces: These furnaces have two heating stages, allowing them to adjust heat output based on the demand. Q: Is there a difference in heat exchangers when it comes to gas or oil furnaces? A: No, the heat exchanger will work the same way and with the same results. f/k/a Goodman Manufacturing Company, L. Cleaning must be done without damaging the heat exchanger Jan 10, 2024 · The recall scope now includes about 3,600 additional units with the following configurations and coil serial numbers, as shown in the table below: Type Coil Configuration Affected Furnace Brands (2) replacement of the secondary heat exchanger in the original furnace with a brand new secondary heat exchanger utilizing the same design at no cost to you. Incidents/Injuries: Goodman has received eleven reports of smoke or fire associated with the PTAC's power cords. In fact, replacing a furnace heat exchanger can take up to 8 hours and can cost anywhere from $2,000 to $3,500. gov/Recalls/2022/Goodman-Manufacturing-Company-Recalls-Evaporator-Coil-Drain-Pans-Installed-with-Condensing-Gas Providing outstanding product is just one way of continuing the Goodman brand's over seventy year promise to homeowners. Keeping that reputation alive means continuous improvement through product innovation and the introduction of new features reflecting advances in technology. Get genuine Goodman factory OEM Heat Exchangers for your Goodman unit. Item Typically Ships Within the Same Business Day; Brand-New Genuine Parts - Everytime Aug 15, 2013 · Goodman 25213-02S Furnace Heat Exchanger (Replaces 25213-02, 25213-02SSNQSNS) Genuine Original Equipment Manufacturer (OEM) Part: Multiroom Air Conditioners: Amazon. Many components Heat exchangers in the furnace can crack. Registration is required Were you recently told that your furnace heat exchanger is cracked and needs to be replaced? If so, here’s the thing: replacing a heat exchanger isn’t as simple or affordable as it sounds. Goodman Manufacturing Company, L. Oct 31, 2015 · Goodman GMH950453BX - Goodman 45,000 BTU 95% Efficiency, Two Stage Burner, Multi-Speed Blower, Upflow/Horizontal Application Gas Furnace- The Goodman GMH95 95% AFUE Two-Stage (Convertible), Multi-Speed, Multi-Position furnaces feature a patented aluminized-steel tubular heat exchanger and durable Silicon Nitride Hot Surface Ignition system. Goodman Furnace Technical Specifications. FIT Recall. These furnaces were installed in the early 90s and virtually al Feb 21, 2023 · A heat exchanger is the crucial gas furnace component that heats the air. Dec 24, 2019 · On a previous service call I went out and found this Goodman gas pack heat exchanger cracked. Time for a new furnace But my next issue is: If the original tech said the heat exchanger was breached, why didn't he shut it down and make a thorough exam on the spot. com Commitment. Nov 18, 2021 · Furnaces in this configuration that were installed or repaired with a new evaporator coil drain pan between January 2019 and November 2021 are affected by this recall. 3. Therefore, installing an old heat exchanger on a new furnace will not be cost-effective. Get your furnace back up and running with DIY instructions and OEM replacement parts. No injuries have been reported. Yeah, we know that’s crazy expensive. Goodman furnaces are a great option for home heating when you need an extremely reliable replacement furnace for a decent price. Apr 9, 2013 · Goodman HVAC Replacement Parts CLICK HERE TO SEARCH OUR DATABASE FOR YOUR UNIT Heat Exchangers. Registration is required Lifetime heat exchanger warranty; 10-year parts warranty; 10-year unit replacement warranty; Curious about the unit replacement warranty? It means that Goodman will replace the entire furnace if the heat exchanger fails during the coverage period. See pic. Inducer Motor: The inducer motor is designed to draw a gas furnace’s exhaust gases away from inside the heat exchanger, so it’s important that it is in proper working condition. Nov 18, 2021 · The molded plastic drain pan located at the bottom of the evaporator coil, when installed with a residential condensing gas furnace in an up-flow configuration, can overheat, melt, and deform, posing a fire hazard. Consumers should visit Goodman’s recall website to use a model verification tool for the evaporator coil, furnace and outdoor condenser. If they are dirty from poor combustion or missing then the draft can be affected. The furnace control checks for an open main limit (this limit is normally closed). A brand new heat exchanger can cause the furnace to fail otherwise. This information is for gas furnaces such as the GMP100-3 and GMP100-4. This retrofit involves 150,000- and 200,000-Btu oil furnaces manufactured by Ducane and distributed under the following brand names and model numbers: Feb 9, 2024 · Mastering Your Goodman Furnace: A Guide to Troubleshooting and Top Performance Mastering Your Goodman Furnace: A Guide to Troubleshooting and Top Performance Keeping your home warm and toasty in winter relies heavily on a perfectly functioning furnace. Its reputation was built on a foundation of quality core product development, manufacturing excellence, and engineering expertise. Jan 10, 2024 · Daikin Comfort Technologies Manufacturing (formerly Goodman Manufacturing Company L. Get genuine Goodman factory OEM Gas Furnace for your Goodman unit. The plenum steel shows no rust or marks from running water. Incidents/Injuries: DCT has received 26 reports of fire involving evaporator coil drain pans, including three reports of fire since the recall was announced in November 2021. COMPONENT UPGRADE OFFERS BETTER PERFORMANCE The aluminized steel, tubular primary heat exchanger featured in Goodman brand gas furnaces is likely the most essential component in a gas furnace’s performance. We get more energy efficiency out of these furnaces because there is more heat transfer over a greater surface area, which we owe to the secondary heat exchanger. Coleman had 223,000 units recalled in 2012, and Trane with 17,700 recalled in 2016. Goodman manufactures both 80% and 90%-plus efficient furnaces in single-stage, two-stage, and Jun 28, 2021 · Like Ducane, Armstrong furnaces also have either an aluminized heat exchanger or a steel heat exchanger. Run the furnace for about 5 mins and subtract the return air temp from that duct or the house temp from the supply temp and compare it to the rating on the model # sticker. P. 2 However, you should always discuss repair vs replacement options with your HVAC technician to get a clearer assessment of the price tag of repairs and the predicted longevity of Oct 9, 2005 · Twilli, it says in your profile your self employed. This distinctive heat exchanger employs wrinkle-bend technology which was developed to deliver extraordinary durability and long-term reliability. A new Goodman furnace with 80% efficiency installed is about 1600$. Consumer Product Safety Commission (“CPSC”) and Health Canada, Daikin Comfort Technologies Manufacturing, L. Feb 9, 2024 · Electrical Problems: Issues like frequent breaker trips or wiring faults need expert attention. If power is getting to the blower motor, but the motor does not run, the motor may be burned out. After the super-hot gases pass out of the primary heat exchanger, they enter the secondary heat exchanger where even more heat is transferred out of the combustion gases before it leaves the flue and is lost. In this Pick HVAC furnace information article, you will learn how to clean a heat exchanger and what warning signs to look for that your heat exchangers need to be Jul 25, 2021 · In order to replace a heat exchanger, you’ll need around $650 to $1200 to buy and install the new exchanger. If your systems are breaking down and need costly repairs within the first months or years of owning them, you may need to upgrade to a higher-quality brand. They explained the dangers of CO2 getting into the house and that the heat exchanger needed replaced or the furnace replaced. just to unload and load my tools back in truck, another 1-hr. 2 SEER2 & up to 7. The heat exchanger is responsible for transferring heat into your home while venting harmful combustion gases outside. Confirm the power switch on the side of the furnace is turned on. com: Tools & Home Improvement This tool helps identify issues like incomplete combustion, which can lead to soot buildup and heat exchanger problems. If the blower motor is burned out, replace it. They demand specialized Mar 27, 2023 · A crack in the secondary heat exchanger or problems with the condensate assembly can lead to water leaking from a furnace. All Goodman Gas Furnace parts are brand new in the original factory packaging and are guaranteed to fit and function properly. The inside of the furnace cabinet has no rust or water signs. ** *Credit available toward purchase of a qualifying Carrier gas furnace; credit includes $200 toward equipment purchase and up to four hours of labor, for a total of up to $525 Sep 22, 2009 · This is part of the heat exchanger. York had the highest amount of recalls in 2004, with 226,000 units recalled. 7401 Security Way Houston, Texas 77040 877-254-4729-Telephone 713-863-2382-Facsimile Goodman Manufacturing Goodman, an American HVAC brand founded by Harold Goodman, is known as the low-cost leader in the furnace market. 5. First, make sure that power is getting to the motor. When a furnace cannot get enough airflow, the heat exchanger overheats and suffers excess stress from expansion and contraction. June 13, 2024. In this HVAC video I go over what a clogged heat exchanger looks like, how the problem arises, the difference between the primary and secondary heat exchange The unit replacement warranty also has to do with the heat exchanger, and it means that Goodman will offer to provide a brand new furnace if the heat exchanger fails within 10 years of installation. If you’re experiencing other problems with your Goodman furnace, I recommend reading through our Complete Goodman Furnace Troubleshooting GLZS4M Energy-Efficient Multi-Family R32 Split System Heat Pump 15. If there is no power to the furnace, check the home's furnace circuit breaker or fuse. This distinctive heat exchanger employs wrinkle-bend Mar 11, 2017 · I was surprised to see significant rust on the primary heat exchanger. 2921306S Oct 5, 2012 · I demonstrate how the GMP 050 to 100 model furnace heat exchanger failure diagnosis is done. About 298,300 evaporator coil drain pans have been recalled by Goodman Manufacturing Company due to a fire hazard. Jun 27, 2024 · Recall Details. The exchanger’s design allows the air inside the furnace to be heated separate from the toxic fuel combustion gasses. 7 billion . Gases like nitrous oxide and sulfur dioxide can cause a very diverse negative effects on humans. Learn more about Goodman products watch this pl Apr 29, 2022 · A secondary heat exchanger is part of any high-efficiency furnace – one with an AFUE efficiency rating of 90% or greater. In 2012, Goodman Global was acquired by Daikin Industries of Osaka, Japan for $3. To receive the Lifetime Compressor Limited Warranty (good for as long as you own your home), Lifetime Heat Exchanger Limited Warranty (good for as long as you own your home), 10-Year or 2-Year Unit Replacement Limited Warranty, 20-Year Heat Exchanger Limited Warranty, and 10-Year Parts Limited Warranty What is a heat exchanger and how does it help a furnace heat the house? Find out by watching this short video. Goodman’s model verification tool provides step-by-step instructions for determining if your gas furnace system is subject to this recall. Apr 29, 2022 · For example, if your furnace has 1/16 of an inch of soot build-up in the heat exchanger, your furnace will lose up to 25% of the heat and have a corresponding increase in fuel usage. For more details on the recall, see https://www. Nov 20, 2021 · Goodman Manufacturing Co. The exchanger’s looped metal tubes start at the burner assembly and end at the flue vent. Apr 22, 2022 · Based on our findings and recall data from the CPSC avoid furnace brands like York, Coleman, Trane, and Goodman. The recalled products have model numbers beginning AMEH80, DM80HE, and GME8, and serial numbers beginning 1609, 1610, 1611 and 1612. Online registration is not required in California or Quebec. 2, which is in line with Energy Star * Complete warranty details available from your local dealer or by clicking on the Product Warranty link above. 8 HSPF2 1½ to 3 Tons Jul 13, 2022 · Goodman furnaces are among the most recognized and respected forced-air heating systems. This recall expansion includes May 2, 2017 · This recall involves 80% efficiency gas-fired furnaces sold under the Goodman, Amana and Daikin brand names used with home heating and cooling systems. Only evaporator drain pans with serial numbers with prefixes ranging from 1901 through 2101 are covered by this recall. 2008) Manufacturer: Goodman Company, LP, of Houston, Texas. This results in improved energy efficiency and better comfort control. 2921300S. Dec 16, 2023 · Get your tech to check with Goodman for any service bulletins. 2921305S. Check to see if there is power to the furnace. Hazard: The power cords on the PTACs can overheat, posing a burn or fire hazard. Aug 5, 2020 · The heat exchanger system begins at the furnace’s burner assembly and ends when the furnace connects to the chimney vent. Package Unit Serial Plate Recall Info. June 27, 2024. he left a customer in a rather dangerous position. The recalled units are beige and the model name is printed on the outside of the unit. The model and serial numbers are found on the serial plate attached to the control compartment A: Yes, all furnaces need a heat exchanger to function properly. uhxa egq cmsrwyt pyufuy fmtdbmo npjre xvjf mbxg wlxn znigm